In a typical private well system in and around St. Charles, the pressure tank holds a cushion of air on one side of a diaphragm or bladder and water on the other. The air is what pushes water to your taps. When the air charge drops or the bladder fails, the pump may start and stop more often than it should, pressure may swing, and taps may sputter. Those symptoms overlap with other problems, so checking the tank is a useful early step.

Safety first

Turn off the pump power at the breaker before touching the tank or its fittings. Pressure tanks can hold water under pressure, so do not loosen fittings while the system is charged. If the breaker panel, pump wiring, or tank area looks damaged, stop and have a qualified person look at it.

A step-by-step check

  1. Turn off the pump breaker and wait until the pump has stopped.
  2. Open the nearest hose bibb or kitchen tap to drain the system so the tank holds no water pressure on its water side.
  3. Locate the air valve on top of the tank, which looks like a tire valve, and remove its cap.
  4. Press a tire style pressure gauge onto the valve and read it.
  5. Compare the reading to the air setting on the tank label or in the manual, which is usually tied to the pressure switch setting.
  6. If the air is low, add a small amount with a hand pump or compressor, checking the gauge as you go, then replace the cap.
  7. Restore power, let the system pressurize, and watch how the pump cycles.

Reading what you find

  • The air holds and the pump cycles normally: the charge is likely fine, so look at other parts of the system, such as the pressure switch or gauge.
  • The air leaks out quickly after you add it: the valve core or a fitting may be leaking.
  • Water comes out of the air valve when you press it: the bladder or diaphragm has likely failed, which is a repair question.
  • The air charge is low but holds after topping off: a slow loss is worth tracking over time.

Common mistakes

Adding air while the tank still holds water pressure gives a false reading. Checking the valve without draining the system first can lead to the wrong conclusion. Over-inflating can stress the tank, so add air in small steps and check again. Write down the date and each reading so you can see whether the charge changes between checks. That record is useful if you later describe the problem to a service provider.

When to call for help

Call a licensed well contractor if water leaks from the tank, if the bladder appears to have failed, if the pump keeps cycling after the air is set correctly, or if the tank is rusted or damaged. Note the tank's age and any visible rust before you call, since both help a contractor size up the problem quickly. Keep the pump and tank area dry and accessible so the next check is easier.